HOME > SBP Series


SBP Series

 AC Coupled Retrofit Solution


Technical Data
GW3600S-BPGW5000S-BP





Battery Input Data

Battery TypeLi-Ion or Lead-acidLi-Ion or Lead-acid
Nominal Battery Voltage ( V )
4848
Max Charging Voltage ( V )
≤60 (Configurable)≤60 (Configurable)
Max Charging Current ( A )*1
75100
Max. Discharging Current (A)*175100
Battery Capacity (Ah)*250~2000
50-2000

Charging Strategy for 

Li-Ion Battery

Self-adaption to BMS
Self-adaption to BMS
AC Output Data (On-grid)

Nominal Power Output to 

Utility Grid (W)

3680
5000*3

Max. Apparent Power Output 

to Utility Grid (VA)*4

36805000

Max. Apparent Power from 

Utility Grid (VA)

73609200
Nominal Output Voltage (V)230230
Nominal Ouput Frequency (Hz)50/6050/60

Max. AC Current Output to 

Utility Grid (A)

1622.8*5

Max. AC Current From 

Utility Grid (A)

3240
Output Power Factor~1 (Adjustable from 0.8 leading to 0.8 lagging)

Output THDi  

(@Nominal Output)

<3%<3%
AC Output Data (Back-up)

Max. Output Apparent 

Power (VA)*6

36805000

Peak Output Apparent 

Power (VA)*6

4416, 10sec
5500, 10sec
Automatic Switch Time (ms)<10
<10
Nominal Output Voltage (V)230 (±2%) 230 (±2%) 
Nominal Output Freqency (Hz)50/60 (±0.2%)50/60 (±0.2%)
Max. Output Current (A)1622.8
Output THDv (@Linear Load)<3%
<3%
Efficiency
Max. Efficiency95.5%
95.5%
Protection
Anti-islanding ProtectionIntegratedIntegrated
Output Over Current ProtectionIntegratedIntegrated
Output Short ProtectionIntegratedIntegrated
Output Over Voltage ProtectionIntegratedIntegrated
General Data

Operating Temperature

Range (℃)

-25~60-25~60
Relative Humidity0~95%0~95%
Operating Altitude(m)40004000
CoolingNature ConvectionNature Convection
Noise (dB)<25<25
User InterfaceLED & APPLED & APP
Communicaiton with BMS*7RS485; CANRS485; CAN
Communicaiton with MeterRS485RS485
Communicaiton with PortalWi-FiWi-Fi
Weight (kg)18.518.5
Size (Width*Height*Depth mm)347*432*190347*432*190
MountingWall Bracket
Wall Bracket
Protection DegreeIP65IP65
Standby Self Consumption (W)<15<15
TopologyHigh Frequency Isolation
Certifications & Standards
Grid RegulationAS/NZS 4777.2:2015, G83/2, G100 CEI 0-21;RD1699;UNE206006; VDE4105-AR-N; VDE0126-1-1; EN50438AS/NZS 4777.2:2015, G59/3, G100, CEI 0-21;RD1699;UNE206006; VDE4105-AR-N; VDE0126-1-1; EN50438
Safety RegulationIEC62477-1, IEC62040-1
EMCEN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4


*1: lead acid battery use refers to battery compatible statement(Not all lead acid batteries are compatible)

     The actual charge and discharge current also depends on the battery

*2: Battery capacity could be not less than 100Ah where the back-up function is to be applied.

*3: 4600 for VDE0126-1-1&VDE-AR-N 4105 and CEI 0-21

*4: For CEI 0-21  GW3600S-BP is 4050,GW5000S-BP is 5100;  for VDE-AR-N4105 GW5000S-BP is 4600

*5: 21.7A for AS4777.2

*6: Can be reached only if battery capacity is enough, otherwise will shut down.

*7: The standard configuration is CAN 